3602 series valves design specifications include:

  • Sizes: ¾”
  • Differential Operating Pressure: 2-150 PSID (2.5-5.0 GPM); 3-150 PSI (5.5-8.0 GPM);  5-150 PSID (8.5-10.0 GPM)
  • Flow Rates: 2.50, 3.00, 3.50, 4.00, 4.50, 5.00, 5.50, 6.00, 6.50, 7.00, 7.50, 8.00, 8.50, 9.00, 9.50, 10.0 GPM
  • Flow Accuracy: +/- 10%
  • Maximum Operating Temperature: 160°F
  • Valves are marked with flow direction arrows, size and flow rate.
  • Hydrostatic Tested @ 450 psi
  • Service Kits Available
  • Tested to Military standards
  • Low Operating PSID replacement for 2351 valve